13 research outputs found

    Acoustic sizing of an ultrasound contrast agent

    Get PDF
    Because the properties of ultrasound contrast agent populations after administration to patients are largely unknown, methods able to study them noninvasively are required. In this study, we acoustically performed a size distribution measurement of the ultrasound contrast agent Definity®. Single lipid-shelled microbubbles were insonified at 25 MHz, which is considerably higher than their resonance frequency, so that their acoustic responses depended on their geometrical cross sections only. We calculated the size of each microbubble from their measured backscattered pressures. The acoustic size measurements were compared with optical reference size measurements to test their accuracy. Our acoustic sizing method was applied to 88 individual Definity® bubbles to derive a size distribution of this agent. The size distribution obtained acoustically showed a mean diameter (2.5 μm) and a standard deviation (0.9 μm) in agreement within 8% with the optical reference measurement. At 25 MHz, this method can be applied to bubble sizes larger than 1.2 μm in diameter. It was observed that similar sized bubbles can give different responses (up to a factor 1.5), probably because of shell differences. These limitations should be taken into account when implementing the method in vivo. This acoustic sizing method has potential for estimating the size distribution of an ultrasound contrast agent noninvasivel

    Sounding out buried nanostructures using subsurface ultrasonic resonance force microscopy

    No full text
    Imaging of nanoscale structures buried in a covering material is an extremely challenging task, but is also considered extremely important in a wide variety of fields. From fundamental research into the way living cells are built up to process control in semiconductor manufacturing would all benefit from the capability to image nanoscale structures through arbitrary covering layers. Combining Atomic Force Microscopy (AFM) with ultrasound has been shown a promising technology to enable such imaging in various configurations. Here we report the development of an alternative method of combining AFM with ultrasound which we call SubSurface Ultrasonic Resonance Force Microscopy (SSURFM) and which is based on a combination of the two most common variants described in literature, which each have their specific strong points: Ultrasonic Force Microscopy (UFM) and Contact Resonance AFM (CR-AFM). We show the excellent performance of this combination on a number of samples designed specifically to mimic relevant conditions for the application as a metrology technique in the semiconductor manufacturing process. We also discuss the physics of the image contrast mechanism which is based on sensing local changes in visco-elastic properties of the sample bygenerating large indentations in the surface

    Transfer functions of US transducers for harmonic imaging and bubble responses

    Get PDF
    Current medical diagnostic echo systems are mostly using harmonic imaging. This means that a fundamental frequency (e.g., 2 MHz) is transmitted and the reflected and scattered higher harmonics (e.g., 4 and 6 MHz), produced by nonlinear propagation, are recorded. The signal level of these harmonics is usually low and a well-defined transfer function of the receiving transducer is required. Studying the acoustic response of a single contrast bubble, which has an amplitude in the order of a few Pascal, is another area where an optimal receive transfer function is important.\ud \ud We have developed three methods to determine the absolute transfer function of a transducer. The first is based on a well-defined wave generated by a calibrated source in the far field. The receiving transducer receives the calibrated wave and from this the transfer functions can be calculated. The second and third methods are based on the reciprocity of the transducer. The second utilizes a calibrated hydrophone to measure the transmitted field. In the third method, a pulse is transmitted by the transducer, which impinges on a reflector and is received again by the same transducer. In both methods, the response combined with the transducer impedance and beam profiles enables the calculation of the transfer function.\ud \ud The proposed methods are useful to select the optimal piezoelectric material (PZT, single crystal) for transducers used in reception only, such as in certain 3D scanning designs and superharmonic imaging, and for selected experiments like single bubble behavior.\ud \ud We tested and compared these methods on two unfocused single element transducers, one commercially available (radius 6.35 mm, centre frequency 2.25 MHz) the other custom built (radius 0.75 mm, centre frequency 4.3 MHz). The methods were accurate to within 15%

    An Algorithm to Minimize the Zero-Flow Error in Transit-Time Ultrasonic Flow Meters

    No full text
    Transit-time ultrasonic flow meters are widely used in industry to measure fluid flow. In practice ultrasonic flow meters either show a zero-flow error or suffer from a significant random error due to a limited signal-to-noise ratio, requiring a significant amount of averaging to achieve good precision. This work presents a method that minimizes the zero-flow error whilst keeping the random error low, independent of the hardware used. The proposed algorithm can adjust to changing zero-flow errors while a flow is present. The technique combines the benefits of two common methods of determining the transit-time difference between the upstream and downstream ultrasonic waves: cross-correlation and zero-crossing detection. The algorithm is verified experimentally using a flow-loop. It is shown that the zero-flow error can be greatly reduced without compromising the random error or increasing circuit complexity

    Super-harmonic imaging: development of an interleaved phased-array transducer

    Get PDF
    For several years, the standard in ultrasound imaging has been second-harmonic imaging. A new imaging technique dubbed "super-harmonic imaging" (SHI) was recently proposed. It takes advantage of the higher-third to fifth-harmonics arising from nonlinear propagation or ultrasound-contrast-agent (UCA) response. Next to its better suppression of near-field artifacts, tissue SHI is expected to improve axial and lateral resolutions resulting in clearer images than second-harmonic imaging. When SHI is used in combination with UCAs, a better contrast-to-tissue ratio can be obtained. The use of SHI implies a large dynamic range and requires a sufficiently sensitive array over a frequency range from the transmission frequency up to its fifth harmonic (bandwidth > 130%). In this paper, we present the characteristics and performance of a new interleaved dual frequency array built chiefly for SHI. We report the rationale behind the design choice, frequencies, aperture, and piezomaterials used. The array is efficient both in transmission and reception with well-behaved transfer functions and a combined -6-dB bandwidth of 144%. In addition, there is virtually no contamination of the harmonic components by spurious transducer transmission, due to low element-to-element crosstalk (< 30 dB) and a low transmission efficiency of the odd harmonics (< 46 dB). The interleaved array presented in this article possesses ideal characteristics for SHI and is suitable for other methods like second-harmonic, subharmonic, and second-order ultrasound field (SURF) imagin

    High-Frequency Surface Dynamics at an Electroactive Polymer Producing Underwater Soundwaves

    No full text
    Coatings with dynamic surface structures are appealing to many applications like haptics and soft robotics. Restrictively, the speed of the surface dynamics in these coatings is often limited to frequencies below 1 kHz, which makes them unsuitable for applications like acoustics and communication optics. This work describes a method to create high-frequency surface dynamics controlled by alternating electric fields on a substrate-contact-modulated coating that consists of an elastic poly(dimethyl siloxane) network supported by SU-8 microstructures. The principle is based on the global application of Maxwell stress that is locally resisted by the supporting SU-8 microstructures. In-between the microstructures the elastic material is stretched, causing a large deformation of the surface topography, which is supported by the authors’ finite element method models. By applying a high-frequency alternating field, they discovered resonance effects at frequencies up to 230 kHz, where the surface of the coating vibrates at high speeds and large amplitudes. At these high frequencies, the coatings can produce and detect ultrasound waves underwater, indicating their potential for ultrasound transducers in the future

    Measurement of Pipe and Liquid Parameters Using the Beam Steering Capabilities of Array-Based Clamp-On Ultrasonic Flow Meters

    Get PDF
    Clamp-on ultrasonic flow meters (UFMs) are installed on the outside of the pipe wall. Typically, they consist of two single-element transducers mounted on angled wedges, which are acoustically coupled to the pipe wall. Before flow metering, the transducers are placed at the correct axial position by manually moving one transducer along the pipe wall until the maximum amplitude of the relevant acoustic pulse is obtained. This process is time-consuming and operator-dependent. Next to this, at least five parameters of the pipe and the liquid need to be provided manually to compute the flow speed. In this work, a method is proposed to obtain the five parameters of the pipe and the liquid required to compute the flow speed. The method consists of obtaining the optimal angles for different wave travel paths by varying the steering angle of the emitted acoustic beam systematically. Based on these optimal angles, a system of equations is built and solved to extract the desired parameters. The proposed method was tested experimentally with a custom-made clamp-on UFM consisting of two linear arrays placed on a water-filled stainless steel pipe. The obtained parameters of the pipe and the liquid correspond very well with the expected (nominal) values. Furthermore, the performed experiment also demonstrates that a clamp-on UFM based on transducer arrays can achieve self-alignment without the need to manually move the transducers

    Exploiting nonlinear wave propagation to improve the precision of ultrasonic flow meters

    No full text
    Acoustic wave propagation in ultrasonic flow measurements is typically assumed to be linear and reciprocal. However, if the transmitting transducer generates a sufficiently high pressure, nonlinear wave propagation effects become significant. In flow measurements, this would translate into more information to estimate the flow and therefore a higher precision relative to the linear case. In this work, we investigate how the generated harmonics can be used to measure flow. Measurements in a custom-made flow loop and simulations using the Khokhlov–Zabolotskaya–Kuznetsov (KZK) equation will show that the second harmonic component provides similar transit time differences to those obtained from the fundamental component, their linear combination results in more precise flow measurements compared to the estimations with the fundamental component alone

    Optimization of a phased-array transducer for multiple harmonic imaging in medical applications: frequency and topology

    Get PDF
    Second-harmonic imaging is currently one of the standards in commercial echographic systems for diagnosis, because of its high spatial resolution and low sensitivity to clutter and near-field artifacts. The use of nonlinear phenomena mirrors is a great set of solutions to improve echographic image resolution. To further enhance the resolution and image quality, the combination of the 3rd to 5th harmonics - dubbed the superharmonics - could be used. However, this requires a bandwidth exceeding that of conventional transducers. A promising solution features a phased-array design with interleaved low- and high-frequency elements for transmission and reception, respectively. Because the amplitude of the backscattered higher harmonics at the transducer surface is relatively low, it is highly desirable to increase the sensitivity in reception. Therefore, we investigated the optimization of the number of elements in the receiving aperture as well as their arrangement (topology). A variety of configurations was considered, including one transmit element for each receive element (1/2) up to one transmit for 7 receive elements (1/8). The topologies are assessed based on the ratio of the harmonic peak pressures in the main and grating lobes. Further, the higher harmonic level is maximized by optimization of the center frequency of the transmitted pulse. The achievable SNR for a specific application is a compromise between the frequency-dependent attenuation and nonlinearity at a required penetration depth. To calculate the SNR of the complete imaging chain, we use an approach analogous to the sonar equation used in underwater acoustics. The generated harmonic pressure fields caused by nonlinear wave propagation were modeled with the iterative nonlinear contrast source (INCS) method, the KZK, or the Burger's equation. The optimal topology for superharmonic imaging was an interleaved design with 1 transmit element per 6 receive elements. It improves the SNR by ~5 dB compared wi- - th the interleaved (1/2) design reported in literature. The optimal transmit frequency for superharmonic echocardiography was found to be 1.0 to 1.2 MHz. For superharmonic abdominal imaging this frequency was found to be 1.7 to 1.9 MHz. For 2nd-harmonic echocardiography, the optimal transmit frequency of 1.8 MHz reported in the literature was corroborated with our simulation result

    Measurement of Pipe and Fluid Properties with a Matrix Array-Based Ultrasonic Clamp-On Flow Meter

    No full text
    Current ultrasonic clamp-on flow meters consist of a pair of single-element transducers that are carefully positioned before use. This positioning process consists of manually finding the distance between the transducer elements, along the pipe axis, for which maximum signal-to-noise ratio (SNR) is achieved. This distance depends on the sound speed, thickness, and diameter of the pipe and on the sound speed of the liquid. However, these parameters are either known with low accuracy or completely unknown during positioning, making it a manual and troublesome process. Furthermore, even when sensor positioning is done properly, uncertainty about the mentioned parameters, and therefore on the path of the acoustic beams, limits the final accuracy of flow measurements. In this research, we address these issues using an ultrasonic clamp-on flow meter consisting of two matrix arrays, which enables the measurement of pipe and liquid parameters by the flow meter itself. Automatic parameter extraction, combined with the beam-steering capabilities of transducer arrays, yields a sensor capable of compensating for pipe imperfections. Three parameter extraction procedures are presented. In contrast to similar literature, the procedures proposed here do not require that the medium be submerged nor do they require a priori information about it. First, axial Lamb waves are excited along the pipe wall and recorded with one of the arrays. A dispersion curve-fitting algorithm is used to extract bulk sound speeds and wall thickness of the pipe from the measured dispersion curves. Second, circumferential Lamb waves are excited, measured, and corrected for dispersion to extract the pipe diameter. Third, pulse-echo measurements provide the sound speed of the liquid. The effectiveness of the first two procedures has been evaluated using simulated and measured data of stainless steel and aluminum pipes, and the feasibility of the third procedure has been evaluated using simulated data